No Air Output (Tank Pressure is Ok)

Manifold Regulator Internally Damaged

Models: 4610, 4620, 5020W, 10020C, 10020CAD, 20020, 20020AD, etc. 

 

Symptoms:
1. Tank Pressure Gauge reads normal and correct (i.e. 120 PSI) which signifies the motor-pump, pressure switch, check valve and unloader valve are functioning correctly.
2. Regulator Pressure Gauge reads zero (0 PSI), or excessively low (i.e. less than 20 PSI), and no air output is available for tooling.

 

Resolve Issue:
1. Turn off and unplug the air compressor.
2. Drain the air tank from the drain valve.
3. Replace the regulator assembly:
    > To order for 4610/4620 series models, click here.
    > To order for 5020W/10020C/20020 series models, click here.
 
NOTE: in some cases cleaning the regulator may correct the issue if pressure is partially available (i.e. 20 PSI range or similar).
4. Remove the regulator body from the manifold with a wrench.
5. Replace the regulator body, air piston, spring, cap and knob.
                           

 

 

 

CAUTION: Replacing the original Industrial Female fitting on a new unit will void your warranty if damage is incurred. The Industrial female fitting (or fittings) is attached with high-grade locktite to the manifold and should only be removed using a heat gun in order to loosen the locktite. The manifold assembly may crack and leak air if improperly modified. For servicing personnel only!

California Air Tools Store - Brand New & Blemished Items
SMART Air Compressors
80 Gal 5.0 Hp 15 CFM
80 Gal 6.0 Hp 20 CFM
60 Gal 3.7 Hp 11.5 CFM
Ideal Job-Site Air Compressor
17-20 cfm 280V 3-Phase
Complete Out-of-Box Solution
CAT-10TL Tankless 1 Hp
ISO 8573 2.3.1 - 98% Dry Air
CAT-33000 Spray Gun, 1.3 mm
8 Gal Aluminum, 1 Hp, 3 CFM, Long-Life Motor, 60 dB
Print | Sitemap
© california air tools inc

This website was created using IONOS MyWebsite.